Y series large high voltage three-phase asynchronous motor

Y,YKS,YQF,YKK and YR,YRKS,YRQF,YRKK series 6kV and 10kV large high-voltage three-phase asynchronous motors (frame numbers 710~1120) are the latest products designed and developed by our company in accordance with the relevant national and industry standards by digesting and introducing advanced motor technology from abroad in the 1980 s. Is the old Y, YR series of replacement products.

key word:

ChangLi Electric

Product Description

1 Overview

Y,YKS,YQF,YKK and YR,YRKS,YRQF,YRKK series 6kV and 10kV large high-voltage three-phase asynchronous motors (frame numbers 710~1120) are the latest products designed and developed by our company in accordance with the relevant national and industry standards by digesting and introducing advanced motor technology from abroad in the 1980 s. Is the old Y, YR series of replacement products.

This series of products are made of sophisticated materials, and have the advantages of high efficiency and energy saving, low noise, low vibration, reliable operation, convenient installation and maintenance.

The power level, electrical performance, installation dimensions and tolerances of this series of motors are in line with the national standard GB755 "Rotating Motor Quota and Performance" International Electrotechnical Commission standard IEC34-1 "Rotating Motor Quota and Performance" and the national standard GB/T13957-2008 "Large Three-phase Asynchronous Motor Basic Series Technical Conditions" and so on.

The protection level of the shell of this series of motors is IP23, IP44, IP54, IP55 and IP56 according to GB4942.1 and IEC34-5 "Protection Level of Rotary Motor Shell. IP23 motor can be made according to user requirements IP44 (duct ventilation) or IPW24 (climate protection type). If the user needs other protection levels can be supplied separately.

The cooling methods of this series of motors are IC01, IC611, and IC81W according to the standards of GB/T1993 and IEC34-6 "Cooling Methods for Rotating Motors. If the user needs other cooling methods can be supplied separately.

The structure and installation type of this series motor is IMB3 (horizontal with foot), which conforms to GB997 and IEC34-7 "motor structure and installation type code.

This series of motors are divided into the following eight series according to rotor type, protection class and cooling method:

Type

Protection level

Cooling method

Rotor Type

squirrel cage rotor

wound rotor

Anti-shower type

IP23

IC01

Y Series

YR Series

Climate protection

IPW24

IC01

YQF Series

YRQF Series

Air-water cooling closed

IP44、IP54、IP55、IP56

IC81W

YKS Series

YRKS Series

Air-air cooling closed

IP44、IP54、IP55、IP56

IC611

YKK Series

YRKK Series

The table in this sample lists the technical data and external installation dimensions of the above series of 6KV and 10kV motors of various specifications, and can be derived from 3kV, 10.5kV and 11kV motors of various specifications.

 

2 Scope of use

This series of motors can be used to drive various general machinery such as compressors, ventilators, water pumps, cutting machine tools, transportation machinery and other mechanical equipment, and are used as prime movers in various industrial and mining enterprises such as mines, machinery, petrochemical industries, power plants, etc. Motors used to drive large rotational inertia blowers, coal mills, rolling mills, winches, crushers, belt conveyors and other machinery shall provide relevant technical data and sign technical agreements when ordering, as the basis for the special design of the motor to ensure the reliable operation of the motor.

Basic conditions for normal operation of the motor:

(1) The altitude is not more than l000m;

(2) The maximum ambient air temperature does not exceed 40 ℃; the minimum ambient air temperature is 5 ℃;

(3) For YKS and YRKS series motors, the temperature of cooling water at the cooling inlet does not exceed 33 ℃, and the minimum temperature is 5 ℃;

(4) The monthly average maximum relative humidity in the wettest month is 90% and the monthly average minimum temperature is not higher than 25 ℃;

(5) Power supply frequency is 50Hz ± l%;

(6) The variation range of the working voltage shall not be greater than ± 5% of the rated voltage;

(7) The motor quota is the continuous working system S1.

 

3 Model description

According to the provisions of GB4831, the motor model is composed of two parts: product code and specification code. The product code is represented by the motor series code, meaning as follows:

Y-squirrel cage rotor three-phase asynchronous motor;

YKS-enclosed squirrel cage rotor three-phase asynchronous motor with air-water cooler;

YQF-climate protection squirrel cage rotor three-phase asynchronous motor.

The specification code consists of center height and number of poles. Examples are as follows:

 

 

4 Structure description

Y is the basic series, the protection level is IP23, and the cooling method is IC01. A variety of motors with different protection levels and cooling methods can be derived, such as YKS (air-water cooling), YQF (climate protection), YKK (air-air cooling) and other series of motors.

The motor adopts the internationally popular box-type structure, and the frame and end cover are made of steel plate welding, with good rigidity and light weight. After removing the protective cover (or cooler), you can observe and touch the inside of the motor, which is convenient for the installation and maintenance of the motor. The stator adopts external press-fitting structure. The stator winding is made of Class F insulating material and anti-corona material. The end of the winding is fixed by special binding process, which is firm and reliable. The whole stator is treated with vacuum pressure impregnated Class F solvent-free paint (VPI). As a result, the motor has excellent and reliable insulation performance and moisture resistance and impact resistance.

Y, YKK series motor rotor with copper cage rotor guide bar and end ring using medium frequency welding, and the rotor copper bar by the slot fastening process, so it has high reliability.

The bearing adopts the end cover type spherical sliding bearing, which has the advantages of strong load capacity and convenient maintenance.

The main outlet box is of sealed structure, and the protection grade is IP54. Generally installed on the right side of the motor (from the shaft extension end), according to user needs can also be installed on the left side. The inlet hole of the outlet box can be switched up, down, left and right. There is a separate ground terminal in the box. When the motor power is 2000kW and above, a secondary outlet box is also installed on the other side of the motor opposite to the main outlet box to lead out the neutral point of the stator three-phase winding.

 

5 Starting of squirrel cage asynchronous motor (Y, YKS, YQF, YKK series)

The rotor of squirrel cage asynchronous motor adopts advanced calculation technology to calculate the starting temperature rise and stress of the squirrel cage rotor, so as to prevent the motor from being damaged early due to the heavy starting load. User is advised to check:

(1) The moment of inertia of the rotating part of the driven mechanical equipment (after conversion to the motor speed) shall not exceed the value of [Load J] in the technical data sheet;

(2) The user's power grid should ensure that the motor terminal voltage during the starting process of the motor is not less than 85% of the rated voltage;

(3) The resistance torque characteristics of the driven machinery are the resistance torque characteristics of water pumps and fans.

Under the above conditions, the motor is allowed to start twice continuously in the actual cold state, and the motor is naturally stopped between two starts; or it is started once in the hot state of the motor. Restarting the motor beyond the above limits shall be after 1 hour of shutdown.

If the moment of inertia of the mechanical rotating part of the motor drive exceeds the value of (load J) in the technical data sheet, or the motor is required to be started frequently, or the motor may be started with heavy load, please contact our company in advance for special design to ensure the reliable starting of the motor.

 

6 Ordering Instructions

Please indicate the following when ordering:

(1) Motor model: Y710-4

(2) Rated frequency: 50Hz

(3) Rated power: 3150kW

(4) Rated voltage: 6kV

(5) Number of poles: 4 poles

(6) Protection grade: IP23

(7) Cooling method: IC01

(8) Installation type: IMB3

(9) Rotation direction: clockwise (looking at the extended end of the motor shaft)

(10) outlet box position: the right side of the motor (facing the extended end of the motor shaft)

 

7 Precautions

(1) Check the moment of inertia of the driven mechanical equipment (after converting to the speed of the motor), please refer to the aforementioned Article 5: Starting of squirrel cage asynchronous motor;

(2) If there are changes in working conditions or other special requirements, a technical agreement must be signed before the goods contract can be signed;

(3) The technical performance data listed in the table within the sample are guaranteed values for reference in design selection and ordering;

(4) With the progress of technology and the revision of relevant domestic and foreign standards, the technical data and dimensions of the sample have changed without notice. Please ask our company for the official outline drawing after ordering.

Recommended Products

Message to us