YK series large high-speed high-voltage three-phase asynchronous motor

YK series high-speed high-voltage motors are large three-phase asynchronous motors. The working environment temperature is 0C ~ 40 C, and the altitude is not more than 90%. Motor winding insulation class is F. Reliable performance under various conditions. After VPI vacuum immersion, the winding has a long life, and the allowable temperature rise of the motor is 80K.

key word:

ChangLi Electric

Category:

Product Description

1 Overview

YK series high-speed high-voltage motors are large three-phase asynchronous motors. The working environment temperature is 0C ~ 40 C, and the altitude is not more than 90%. Motor winding insulation class is F. Reliable performance under various conditions. After VPI vacuum immersion, the winding has a long life, and the allowable temperature rise of the motor is 80K.

The motor has two shaft extension ends, and either end can be used to drive the supporting machinery. The electric current is generated between the bearing at one end of the motor and the bottom plate.

This series of products with exquisite materials, sophisticated manufacturing, with high efficiency and energy saving, low noise, small vibration, reliable operation, easy installation and maintenance

 

2 Model description

The motor model is composed of three parts: product code, specification code and environment code. The product code is represented by the motor series code, meaning as follows:

YK-Large high-speed high-voltage three-phase asynchronous motor.

The specification code consists of power, number of poles and outer diameter of stator punch. Examples are as follows:

 

 

3 Structure description

The motor adopts the internationally popular box-type structure, and the frame and end cover are made of steel plate welding, with good rigidity and light weight. After removing the protective cover (or cooler), you can observe and touch the inside of the motor, which is convenient for the installation and maintenance of the motor.

The stator adopts external press-fitting structure. The stator winding is made of Class F insulating material and anti-corona material. The end of the winding is fixed by special binding process, which is firm and reliable. The whole stator is treated with vacuum pressure impregnated Class F solvent-free paint (VPI). As a result, the motor has excellent and reliable insulation performance and moisture resistance and impact resistance.

This series motor adopts seat type sliding bearing, motor with mounting base. The basic type of protection level is IP23, IP44, IP54. If the motor has a higher protection level, the protection level of the bearing will also increase. Generally, pressure circulation lubrication is adopted, and the user needs to configure the dilute oil station according to the bearing oil quantity provided by our company.

The rotor fan adopts the axial flow fan with high efficiency and low noise. Because the fan ventilation is directional, the motor needs to rotate in the specified direction and cannot be reversed.

The main junction box is of sealed structure, and the protection grade is IP54. This series of motors are designed with two cylindrical shaft extensions of the same size, and users can choose one shaft extension as the transmission end.

 

4 Ordering Instructions

Please indicate the following when ordering:

(1) Motor model: YK5000-2/1430

(2) Rated frequency: 50Hz

(3) Rated power: 5000kw

(4) Rated voltage: 10kV

(5) Number of poles: 2 poles

(6) Cooling method: IC01

(7) Installation type: IM7212

(8) Protection grade: IP23

(9) Rotation direction: clockwise (looking at the extended end of the motor shaft)

(10) outlet box position: the right side of the motor (facing the extended end of the motor shaft)

(11) Space heaters and temperature measuring elements shall be installed.

 

5 Considerations

(1) Check the moment of inertia of the driven mechanical equipment (after conversion to the speed of the motor).

(2) If there are changes in working conditions or other special requirements, a technical agreement must be signed before the goods contract can be signed.

(3) The technical performance data listed in the table in the sample are guaranteed values, which are close to the actual values for reference in design selection and ordering, but cannot be hung up. The standards for evaluating motors shall be based on the corresponding technical conditions.

(4) With the progress of technology and the revision of relevant domestic and foreign standards, the technical data and dimensions in the sample have changed, without notice, the company will ask for the official outline after ordering.

(5) Under the above conditions, the motor is allowed to start twice continuously in the actual cold state, and the motor is naturally stopped between the two starts; or the motor starts once in the hot state. Restarting the motor beyond the above limits shall be after 1 hour of shutdown.

(6) If the moment of inertia of the mechanical load rotating part of the motor drive exceeds the (load J) value in the technical data sheet, or the motor that requires frequent starting, or the motor that may start with heavy load, be sure to contact our company in advance Negotiate for special design to ensure the reliable starting of the motor

Recommended Products