YR series low voltage three-phase asynchronous motor

YR315 ~ 355(IP23) series of small low-voltage three-phase asynchronous motor is my company's newly designed products, beautiful appearance, novel style, some technical and economic indicators have reached the international advanced level. These products have been mass-produced and exported to more than 20 countries and regions such as Europe, the United States, Africa, Hong Kong and Macao and all over the country, and are well received by users.

key word:

ChangLi Electric

Product Description

1 Overview

YR315 ~ 355(IP23) series of small low-voltage three-phase asynchronous motor is my company's newly designed products, beautiful appearance, novel style, some technical and economic indicators have reached the international advanced level. These products have been mass-produced and exported to more than 20 countries and regions such as Europe, the United States, Africa, Hong Kong and Macao and all over the country, and are well received by users.

This series of products are made of sophisticated materials, and have the advantages of high efficiency and energy saving, low noise, low vibration, reliable operation, convenient installation and maintenance.

The power level, electrical performance, installation dimensions and tolerances of this series of motors are in line with the national standard GB755 "Rotating Motor Quota and Performance" International Electrotechnical Commission standard IEC34-1 "Rotating Motor Quota and Performance" and the mechanical industry standard JB 5272-91,JB5269-91, etc.

The protection level of the shell of this series of motors is IP23 according to GB4942.1 and IEC34-5 "protection level of rotating motor shell.

The cooling method of this series of motors is IC01 according to GB/T1993-93 and IEC34-6 "Cooling Methods for Rotating Electrical Machines.

The structure and installation type of this series of motors are IMB3 (horizontal with feet, end cover without flange),IMV1 (shaft extending downward, lower end cover with flange), which conforms to GB997 and IEC34-7 "Motor Structure and Installation Type Code.

The table in this sample lists the technical data and installation dimensions of 380V grade motors of various specifications, and can derive 440V, 660V grade motors of various specifications.

2 Scope of use

This series of motors can be used to drive various general machinery such as compressors, ventilators, water pumps, cutting machine tools, transportation machinery and other mechanical equipment, and are used as prime movers in various industrial and mining enterprises such as mines, machinery, petrochemical industries, power plants, etc. Motors used to drive large rotational inertia blowers, coal mills, rolling mills, winches, crushers, belt conveyors and other machinery shall provide relevant technical data and sign technical agreements when ordering, as the basis for the special design of the motor to ensure the reliable operation of the motor.

YR(IP23) series motors can provide larger locked-rotor torque under smaller locked-rotor current and can adjust speed within a certain range. It is widely used in the following occasions:(1) larger locked-rotor torque than squirrel cage type is required;(2) The capacity of transmission line is not enough to start squirrel cage motor;(3) The starting time is longer and the starting is more frequent;(4) Need to adjust the speed within a small range;(5) The "electric shaft" is connected for synchronous rotation, etc.; such as compressors, presses, winches, wire drawing machines, conveyors, printing machines, etc.

Basic conditions for normal operation of the motor:

a The altitude is not more than l000m;

B The maximum ambient air temperature does not exceed 40 ℃; the minimum ambient air temperature is -15 ℃;

c The wettest monthly average maximum relative humidity is 90% and the monthly average minimum temperature is not higher than 25 ℃;

d Power supply frequency is 50Hz ± l%;

e The working voltage variation range shall not be greater than ± 5% of the rated voltage;

f The motor rating is S1 of continuous working system;

 

3 Model description

According to the provisions of GB4831, the motor model is composed of two parts: product code and specification code. The product code is represented by the motor series code, which means as follows

Y-squirrel cage rotor three-phase asynchronous motor

YR-wound rotor three-phase asynchronous motor

The specification code consists of center height, core length serial number and pole number.

Example:

 

 

4 Structure description

The motor base and end cover are made of high-strength cast iron, and the stator is of external press-fit structure. The central high -315 and 355 stator winding adopts flat copper formed hard winding or round copper wire scattered embedded soft winding, and adopts B- class or F-class insulating material. The winding end is fixed by special binding process, which is firm and reliable. The whole stator is treated by vacuum pressure impregnation of F-class solventless paint (VPI). Therefore, the motor has excellent and reliable insulation performance, moisture resistance and impact resistance.

The squirrel cage rotor of this series of motors adopts cast aluminum rotor, which is reliable in operation. The winding rotor adopts F-class insulating material and is treated with vacuum pressure impregnated F-class solvent-free paint (VPI).

The bearings are rolling bearings, and their protection class is IP23.

315~355 motors are equipped with non-stop oil filling and oil discharge devices, and special oil filling tools can be used for non-stop oil filling and oil discharge.

The main outlet box is of sealed structure, and the protection grade is IP54. Generally installed on the right side of the motor (from the shaft extension end), according to user needs can also be installed on the left side. There is a separate ground terminal in the outlet box.

 

5 Starting of squirrel cage asynchronous motor (Y series)

The rotor of squirrel cage asynchronous motor adopts advanced calculation technology to calculate the starting temperature rise and stress of the squirrel cage rotor, so as to prevent the motor from being damaged early due to the heavy starting load. It is suggested that the user check:(1) the moment of inertia of the rotating part of the driven mechanical equipment (after conversion to the motor speed) should not exceed the value of [load J] in the technical data sheet;(2) The user's power grid shall ensure that the motor terminal voltage during the starting process of the motor is not less than 85% of the rated voltage;(3) The resistance torque characteristics of the driven machinery are the resistance torque characteristics of water pumps and fans.

Under the above conditions, the motor is allowed to start twice continuously in the actual cold state, and the motor is naturally stopped between two starts; or it is started once in the hot state of the motor. Restarting the motor beyond the above limits shall be after 1 hour of shutdown.

If the moment of inertia of the mechanical rotating part of the motor drive exceeds the [load J] value in the technical data sheet, or the motor is required to be started frequently, or the motor may be started with heavy load, please contact our company in advance for special design to ensure the reliable starting of the motor.

 

6 Ordering Instructions

Please indicate the following when ordering:

(1) Motor model: (Y355M1-6)

(2) Rated frequency: (50Hz)

(3) Rated power: (185kW)

(4) Rated voltage: (380)

(5) Number of poles: (6 poles)

(6) Protection grade: (IP23)

(7) Cooling method: (IC01)

(8) Installation type: (IMB3)

(9) Rotation direction: (clockwise direction [looking at the extended end of the motor shaft)

(10) outlet box position: (the right side of the motor [facing the extended end of the motor shaft)

 

7 Precautions

1. Check the moment of inertia of the driven mechanical equipment (after converting to the speed of the motor), please refer to the above Chapter 5: Starting of squirrel cage motor;

2, such as changes in working conditions or other special requirements, need to sign another technical agreement before signing the goods contract;

3. The technical performance data listed in the table in the sample are all design values, which are close to the actual values for reference in design selection and ordering, but cannot be used as assessment standards. The assessment standards for motors shall be based on corresponding technical conditions;

4. With the progress of technology and the revision of relevant domestic and foreign standards, the technical data and dimensions in the sample have changed without notice. Please ask our company for the official outline drawing after ordering.

Recommended Products